Conference Agenda
Overview and details of the sessions of this conference. Please select a date or location to show only sessions at that day or location. Please select a single session for detailed view (with abstracts and downloads if available).
|
Daily Overview |
| Session | |||||||||||||||
4.6: Credibility assessment, verification and validation of digital twins (Musculoskeletal/Orthopaedics) & Poster session (Different topics)
| |||||||||||||||
| Presentations | |||||||||||||||
8:30am - 8:42am
ID: 290 / 4.6: 1 FEMUR FRACTURE PREDICTION IN POSTMENOPAUSAL WOMEN: MULTI-COHORT CLINICAL VALIDATION OF BBCT-HIP PIPELINE 1Department of Industrial Engineering, University of Bologna; 2Medical Technology Laboratory, IRCCS Istituto Ortopedico Rizzoli, Bologna; 3SSD Medicina e Reumatologia, IRCCS Istituto Ortopedico Rizzoli, Bologna; 4Mechanical, Aerospace and Civil Engineering & INSIGNEO Institute for In Silico Medicine, University of Sheffield
8:42am - 8:54am
ID: 132 / 4.6: 2 PHANTOMLESS CALIBRATION FOR THE ESTIMATION OF BONE STRENGTH IN PAEDIATRIC FEMORA 1School of Mechanical, Aerospace & Civil Engineering, University of Sheffield, United Kingdom; 2Insigneo Institute, University of Sheffield, United Kingdom; 3School of Medicine and Population Health, University of Sheffield, United Kingdom
8:54am - 9:06am
ID: 261 / 4.6: 3 FROM ASTM F543 PHYSICAL TESTING TO IN SILICO EVIDENCE: CREDIBILITY ASSESSMENT OF A DEVICE-AGNOSTIC FE MODEL 1Numalogics; 2École de Technologie Supérieure
9:06am - 9:18am
ID: 156 / 4.6: 4 TOWARDS THE VIRTUAL MOUSE TWIN FOR PRE-CLICNICAL TESTING OF NEW TREATMENTS FOR OSTEOPOROSIS 1The University of Sheffield, United Kingdom; 2Queensland University of Technology, Australia
9:18am - 9:30am
ID: 335 / 4.6: 5 A DYNAMIC MUSCULAR-ARTICULAR DATASET FOR LOWER LIMB DIGITAL TWINS: FIRST APPLICATION AND IN VIVO VALIDATION 1Department of Industrial Engineering, University of Bologna, Italy; 2LBMC UMR_T 9406, University Eiffel - University Lyon 1, France
9:30am - 9:42am
ID: 363 / 4.6: 6 PHANTOM TYPE MATTERS: A BENCHTOP VALIDATION OF FEMUR STRENGTH DETERMINATION WITH FINITE ELEMENT MODELS 1ETH Zürich, Switzerland; 2Singapore-ETH Center, Singapore; 3University of Bologna, Italy; 4Kuopio University Hospital, Finland; 5Lund University, Sweden; 6University of Sheffield, United Kingdom
9:42am - 9:54am
ID: 409 / 4.6: 7 CLINICAL METRIC ERRORS INDUCED BY THE PROPAGATION OF LANDMARKING UNCERTAINTY IN AUTOMATED TKA PLANNING 1TIMC, Univ. Grenoble Alpes, CNRS, France; 2Grenoble-Alpes CHU, France; 3Twinsight, France; 4GH Diaconesses Croix St-Simon, France; 5Univ. Rennes, Inria, CNRS, France
9:54am - 9:57am
ID: 514 / 4.6: 8 SIMULATION OF THE ABDOMINAL WALL FOR PERSONALIZED HERNIA ASSESSMENT 1Faculty of Engineering, University of Porto, Portugal; 2LAETA/INEGI; 3Ii3s, University of Porto, Portugal
9:57am - 10:00am
ID: 298 / 4.6: 9 GEMINI: DIGITAL TWIN FOR PERSONALIZED ISCHEMIC STROKE TREATMENT DEVICE SELECTION: A STUDY PROTOCOL 1Department of Radiology and Nuclear Medicine, Amsterdam UMC, The Netherlands; 2Department of Biomedical Engineering and Physics, Amsterdam UMC, The Netherlands; 3Department of Neurology, Amsterdam UMC, The Netherlands; 4Department of Neurology, Erasmus MC, The Netherlands; 5Department of Radiology and Nuclear Medicine, Erasmus MC, The Netherlands; 6Department of Public Health, Erasmus MC, The Netherlands; 7Department of Biomedical Engineering, Erasmus MC, The Netherlands; 8Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials, and Chemical Engineering, Politecnico di Milano, Italy
10:00am - 10:03am
ID: 325 / 4.6: 10 INTER-RATER VARIABILITY OF BONE FRAGMENT SEGMENTATION AND SURGICAL REDUCTION IN COMPLEX TIBIA FRACTURES 1Institute for Biomechanics, ETH Zurich, Zurich, Switzerland; 2CustomSurg AG, Zurich, Switzerland
10:03am - 10:06am
ID: 257 / 4.6: 11 CALIBRATION OF A BIOCHEMO-MECHANO MULTI-SCALE COMPUTATIONAL MODEL TO PREDICT BONE ADAPTATION 1The University of Sheffield, United Kingdom; 2Queensland University of Technology, Australia
10:06am - 10:09am
ID: 434 / 4.6: 12 CREDIBILITY ASSESSMENT APPROACH FOR VIRTUAL IMPLANT TESTING OF CUSTOM-MADE CRANIOMAXILLOFACIAL DEVICES Engineering inSilico, KLS Martin SE & Co. KG, Germany
10:09am - 10:12am
ID: 233 / 4.6: 13 IMPACT OF ANISOTROPIC MUSCLE CONDUCTIVITY ON PHRENIC NERVE ACTIVATION THRESHOLDS 1Technische Universität Ilmenau, Germany; 2neuroConn GmbH, Germany
10:12am - 10:15am
ID: 258 / 4.6: 14 FROM STANDARDS TO PRACTICE: SCALABLE CREDIBILITY ASSESSMENT OF VIRTUAL PHYSIOLOGICAL HUMAN MODELS 1Sano - Centre for Computational Medicine, Poland; 2Academic Computer Centre Cyfronet AGH, Poland
10:15am - 10:18am
ID: 520 / 4.6: 15 VERIFICATION AND VALIDATION OF MDSIM’S ATLAS SPINE MODEL: APPLICATION TO A PATIENT-SPECIFIC DEFORMITY CASE MDsim, Luxembourg
| |||||||||||||||