Session | ||
SES-A7: Airborne disease transmission
| ||
Presentations | ||
ID: 1382
/ SES-A7: 1
Extended abstracts / Full papers Oral presentation ONLINE Topics: 5c. Monitoring of indoor air quality - Analytics and sensors, 8a. Cleaning, hygiene and prevention of disease transmission - Surface contamination, air quality, 11a. Building simulation and modelling - Air distribution, 11b. Building simulation and modelling - Interaction of structures and IEQ Keywords: SARS-CoV-2, ventilation, Wells-Riley, Tracer studies, SF6 Coupling Tracer Derived ACH with Risk Calculators to Calculate Risk of COVID-19 Infection Prezant Environmental, Australia ID: 1655
/ SES-A7: 2
Extended abstracts / Full papers Oral presentation ONSITE Topics: 1a. Indoor air quality, health and wellbeing - Biologicals, gaseous, particles, 8c. Cleaning, hygiene and prevention of disease transmission - Disinfection, 11a. Building simulation and modelling - Air distribution Keywords: Diffuse ceiling ventilation system, indoor air quality, Computational fluid dynamics, tracer gas, Covid-19 Assessment of diffuse ceiling ventilation performance on transmission of airborne infectious diseases KTH Royal Institute of Technology, Sweden ID: 1294
/ SES-A7: 3
Extended abstracts / Full papers Oral presentation ONSITE Topics: 1a. Indoor air quality, health and wellbeing - Biologicals, gaseous, particles, 8a. Cleaning, hygiene and prevention of disease transmission - Surface contamination, air quality, 11a. Building simulation and modelling - Air distribution Keywords: COVID-19 infection risk, Wells-Riley equation, airborne transmission, CO2 concentration, 3D office environment COVID-19 airborne transmission risk calculation using CO2 concentrations in a 3D office environment 1Cyprus University of Technology, Cyprus; 2Lelantus Innovations Ltd, Nicosia, Cyprus ID: 1428
/ SES-A7: 4
Extended abstracts / Full papers Oral presentation ONSITE Topics: 11a. Building simulation and modelling - Air distribution Keywords: Infected breath, exposure, CFD, classrooms, natural ventilation Assessing exposure to infected breath in naturally ventilated classrooms Imperial College London, United Kingdom ID: 1783
/ SES-A7: 5
Extended abstracts / Full papers Oral presentation ONSITE Topics: 11a. Building simulation and modelling - Air distribution Keywords: SARS-CoV-2; Virus airborne transmission; Air distribution method; Zonal modeling; Infection risk Transient zonal modeling of SARS-CoV-2 airborne infection risk for incomplete mixing air distribution methods 1The Arctic University of Norway, Norway; 2Norwegian University of Science and Technology - NTNU; 3Tallinn University of Technology,; 4Technical University of Denmark ID: 1396
/ SES-A7: 6
Extended abstracts / Full papers Oral presentation ONSITE Topics: 1a. Indoor air quality, health and wellbeing - Biologicals, gaseous, particles Keywords: Risk of infection, Ventilation, Air distribution, Exposure, COVID-19 Can CO2 be used as an indicator of the probability of cross-infection? 1Technical University of Denmark, Department of Civil Engineering, Denmark; 2Silesian University of Technology, Department of Heating, Ventilation and Dust Removal Technology, Poland; 3Silesian University of Technology, Department of Digital Systems, Poland |