Conference Agenda
| Session | ||||||||||||||
D7: Joint replacement I
| ||||||||||||||
| Presentations | ||||||||||||||
8:30am - 8:41am
EFFICACY OF REAL-TIME FEEDBACK ASSISTED EXERCISE THERAPY IN PATIENTS FOLLOWING TOTAL HIP ARTHROPLASTY 1: University of Applied Sciences Campus Vienna, Health Sciences, Vienna, Austria; 2: Orthopedic Hospital Speising, II. Orthopedic Department, Vienna, Austria; 3: University of Vienna, Centre for Sport Science and University Sports, Vienna, Austria; 4: BG Unfallklinik Murnau, Institute for Biomechanics, Murnau, Germany; 5: Paracelsus Medical University, Institute for Biomechanics, Salzburg, Austria
8:41am - 8:52am
IN VIVO GELENKBELASTUNG BEI SPORTLICHEN AKTIVITÄTEN UND DEREN RISIKOEINORDNUNG FÜR POSTOPERATIVE RETURN-TO-SPORT-EMPFEHLUNGEN 1: Julius Wolff Institut, Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Berlin, Germany; 2: Center for Musculoskeletal Surgery, Charité – Universitätsmedizin Berlin, Berlin, Germany
8:52am - 9:03am
EINFLUSS VON FEMUR-WEICHGEWEBE-SYSTEM UND IMPAKTORDESIGN AUF DIE IMPLANTATION ZEMENTFREIER HÜFTTOTALENDOPROTHESEN 1: Institut für Biomechanik, Technische Universität Hamburg, Hamburg, Deutschland; 2: Orthopädie, Asklepios Klinik Barmbek, Hamburg, Deutschland; 3: Institut für Rechtsmedizin, Universitätsklinikum Hamburg-Eppendorf, Hamburg, Deutschland
9:03am - 9:14am
PARADOXICAL KINEMATICS AT THE TIBIAL PLATEAU AFTER TKA: NO EVIDENCE OF PATHOLOGICAL ANTERIOR JOINT SURFACE MOTION 1: Berlin Institute of Health at Charité – Universitätsmedizin Berlin, Julius Wolff Institute, Berlin, Germany; 2: Krankenhaus Märkisch-Oderland GmBH, Wriezen, Germany; 3: Zuse Institut Berlin, Berlin, Germany
9:14am - 9:25am
KNORPELVERSCHLEIß IN DER SCHULTER-HEMIARTHROPLASTY: ENTWICKLUNG EINES NEUEN TESTVERFAHRENS 1: Sektion für Biomechanik und Implantatforschung, Universitätsklinikum Heidelberg, Germany; 2: Forschungszentrum für experimentelle Orthopädie, Universitätsklinikum Heidelberg, Deutschland
9:25am - 9:36am
VERHALTEN ZEMENTFREIER PRIMÄRSCHÄFTE MIT UND OHNE KRAGEN UNTER KONTROLLIERTER UND EXTREMER DYNAMISCHER BELASTUNG 1: Technische Universität Hamburg, Germany; 2: Musgrave Park Hospital Belfast, Northern Ireland; 3: Universitätsklinikum Hamburg Eppendorf, Germany
9:36am - 9:47am
IN VITRO FUNDAMENTALS OF ACOUSTIC EMISSION ANALYSIS FOR EARLY DETECTION OF TOTAL HIP ARTHROPLASTY LOOSENING 1: Laboratory for Biomechanics and Biomaterials (LBB), Hannover Medical School, Hannover, Germany; 2: Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Germany
| ||||||||||||||